High Resistance Decade Meatest M194

رمز التخزين التعريفي : MEM194
يصنع : MEATEST
نموذج : M194
التوفر : في الأوراق المالية

High Resistance Decade Meatest M194

Calibration of insulation testers and megohmmeters
Resistance range 10.00 kΩ 100.0 GΩ
Resistance accuracy 0.1 to 1 %
Maximum test voltage 6 kV
Short current mA meter
Hot switching
Timing function
RS232 (optionally USB, IEEE488, Ethernet) 

M194 High Resistance Decade is based on M6xx Series Real-Resistance
Programmable Decades, providing cutting-edge performance, user-friendly
calibration of resistance ranges as well as test meter ranges, timer and short
current testing of UUTs. Main feature of M194 is adjustable high resistance
decade in continuous range from 10 kΩ to 100 GΩ with 4 digit resolution.
Designed for maximum operating voltages of up to 6 kVDC this decade is
great for calibration of meggers, megohmmeters and insulation testers.
Accuracy from 0.1 %.


Full remote control and automated calibration support is a standard for all
Meatest instruments. On top of that, M194 comes with 4 interfaces (RS232, USB,
LAN and GPIB) to match your system more easily

Model

MEATEST M194

Product Type

High Resistance Decade

Resistance Range

10 kΩ to 100 GΩ

Maximum Test Voltage

6 kVDC (6.3 kV max.)

Resistance Accuracy

0.1% to 1%

Resolution

4-digit programmable

Built-in Meter

DC Voltage & DC Current

Voltage Meter Range

50 V to 6.3 kV

Current Meter Range

0 to 10 mA

Hot Switching

Up to 6 kVDC

Interfaces

RS232 standard; USB, LAN, GPIB optional

Applications

Calibration of insulation testers, megohmmeters, HIPOT & safety testers

1. What is the MEATEST M194?
The M194 is a programmable high-resistance decade box designed for calibrating insulation testers, megohmmeters, HIPOT testers, and other high-resistance measuring instruments up to 6 kV.

2. What is the resistance range?
The M194 provides a programmable resistance range from 10 kΩ to 100 GΩ.

3. What is the maximum operating voltage?
It supports test voltages up to 6 kVDC (6.3 kV maximum).

4. What is the resistance accuracy?
The resistance accuracy ranges from 0.1% to 1%, depending on the selected resistance value.

5. Does the M194 have a built-in test signal meter?
Yes. It includes a built-in meter to measure DC test voltage and short-circuit current.

6. What is the DC voltage measurement range?
The built-in voltmeter measures from 50 V to 6.3 kV DC.

7. What is the DC current measurement range?
The built-in ammeter measures 0 to 10 mA DC.

8. Does it support hot switching?
Yes. The M194 supports hot switching up to 6 kVDC, allowing safe resistance changes during testing.

9. What communication interfaces are available?
It comes standard with RS-232, with optional USB, LAN (Ethernet), and GPIB (IEEE-488) interfaces.

10. Can it be used in automated calibration systems?
Yes. It supports full remote control and automated calibration using standard communication interfaces.

11. What are its main applications?
It is ideal for calibrating insulation testers, megohmmeters, safety testers, and HIPOT testers.

12. What are the key features of the M194?
Key features include a 10 kΩ–100 GΩ range, 6 kV operation, hot switching, built-in voltage/current meter, timing function, and remote control capability.

High Resistance Decade Meatest M194

Calibration of insulation testers and megohmmeters
Resistance range 10.00 kΩ 100.0 GΩ
Resistance accuracy 0.1 to 1 %
Maximum test voltage 6 kV
Short current mA meter
Hot switching
Timing function
RS232 (optionally USB, IEEE488, Ethernet) 

M194 High Resistance Decade is based on M6xx Series Real-Resistance
Programmable Decades, providing cutting-edge performance, user-friendly
calibration of resistance ranges as well as test meter ranges, timer and short
current testing of UUTs. Main feature of M194 is adjustable high resistance
decade in continuous range from 10 kΩ to 100 GΩ with 4 digit resolution.
Designed for maximum operating voltages of up to 6 kVDC this decade is
great for calibration of meggers, megohmmeters and insulation testers.
Accuracy from 0.1 %.


Full remote control and automated calibration support is a standard for all
Meatest instruments. On top of that, M194 comes with 4 interfaces (RS232, USB,
LAN and GPIB) to match your system more easily

Model

MEATEST M194

Product Type

High Resistance Decade

Resistance Range

10 kΩ to 100 GΩ

Maximum Test Voltage

6 kVDC (6.3 kV max.)

Resistance Accuracy

0.1% to 1%

Resolution

4-digit programmable

Built-in Meter

DC Voltage & DC Current

Voltage Meter Range

50 V to 6.3 kV

Current Meter Range

0 to 10 mA

Hot Switching

Up to 6 kVDC

Interfaces

RS232 standard; USB, LAN, GPIB optional

Applications

Calibration of insulation testers, megohmmeters, HIPOT & safety testers

1. What is the MEATEST M194?
The M194 is a programmable high-resistance decade box designed for calibrating insulation testers, megohmmeters, HIPOT testers, and other high-resistance measuring instruments up to 6 kV.

2. What is the resistance range?
The M194 provides a programmable resistance range from 10 kΩ to 100 GΩ.

3. What is the maximum operating voltage?
It supports test voltages up to 6 kVDC (6.3 kV maximum).

4. What is the resistance accuracy?
The resistance accuracy ranges from 0.1% to 1%, depending on the selected resistance value.

5. Does the M194 have a built-in test signal meter?
Yes. It includes a built-in meter to measure DC test voltage and short-circuit current.

6. What is the DC voltage measurement range?
The built-in voltmeter measures from 50 V to 6.3 kV DC.

7. What is the DC current measurement range?
The built-in ammeter measures 0 to 10 mA DC.

8. Does it support hot switching?
Yes. The M194 supports hot switching up to 6 kVDC, allowing safe resistance changes during testing.

9. What communication interfaces are available?
It comes standard with RS-232, with optional USB, LAN (Ethernet), and GPIB (IEEE-488) interfaces.

10. Can it be used in automated calibration systems?
Yes. It supports full remote control and automated calibration using standard communication interfaces.

11. What are its main applications?
It is ideal for calibrating insulation testers, megohmmeters, safety testers, and HIPOT testers.

12. What are the key features of the M194?
Key features include a 10 kΩ–100 GΩ range, 6 kV operation, hot switching, built-in voltage/current meter, timing function, and remote control capability.

قارن بين المنتجات

{"one"=>"حدد 2 أو 3 عناصر للمقارنة", "other"=>"تم اختيار {{ count }} من 3 عناصر"}

حدد العنصر الأول للمقارنة

حدد العنصر الثاني للمقارنة

حدد العنصر الثالث للمقارنة

يقارن