Hi pot Tester Microtest 7631 (8 Channel)
MICROTEST 7631 is a 3-in-1 test instrument that supports AC withstand voltage, DC withstand voltage, and insulation resistance testing functions. It has a maximum AC withstand voltage of 5000V with a leakage current of 30mA, a maximum DC withstand voltage of 6000V with a leakage current of 10mA, and a maximum insulation resistance of 12000MΩ. It provides 8 sets of testing channels and can be optionally equipped with the 7508/7516 multi-channel scanning box, allowing up to 72 sets of testing channels. It supports PC connection software for remote programming and storage of test data. It can also be linked to a barcode scanner for barcode scanning, facilitating production traceability management.
- 8 Channels
- Hi pot ACW 5KV/30mA
- Hi pot DCW 6KV/10mA
- Insulation 1KV/12000MΩ
- Arcing detection
- True RMS measurement circuit
- Measuring Time (0.1 ~ 999s)
- Adjustable ramp time (0.1 ~ 10s)
- Safety Switch(INTER LOCK)
- Option PC Link Software
- 7508/7516 (8/16 channels) expansion box
- Support AC 5000V, DC 6000V, Insulation Resistance 12GΩ
Specification | Details |
Model | 7631 |
Test Channels | 8 |
Product Type | 3-in-1 Hi-Pot / Safety Tester |
AC Hipot Output Voltage | 10 V–5000 V |
AC Voltage Resolution | 1 V |
AC Voltage Accuracy | ±(3% of setting + 5 V) |
AC Rated Current | 30 mA maximum |
AC Leakage Current | 0.001–31 mA |
AC Leakage Resolution | 0.001 mA |
AC Arcing Detection | 0–20 levels; level 1 is most sensitive |
DC Hipot Output Voltage | 10 V–6000 V |
DC Voltage Resolution | 1 V |
DC Voltage Accuracy | ±(3% of setting + 5 V) |
DC Rated Current | 10 mA maximum |
DC Leakage Current | 0.001–11 mA |
DC Leakage Resolution | 0.001 mA |
DC Arcing Detection | 0–10 levels; level 1 is most sensitive |
Insulation Resistance Voltage | 10–1000 V DC |
Insulation Resistance Range | 1–12000 MΩ |
IR Resolution | 1 MΩ |
IR Accuracy | 100–500 V: 1–1000 MΩ ±5%; 500–1000 V: 2–12000 MΩ ±5% |
Measuring Time | 0.1–999 s |
Measuring Time Resolution | 0.1 s |
Ramp Time | 0.1–10 s |
Measurement Circuit | True RMS |
Safety Switch | INTER LOCK |
Built-in Storage | 15 sets |
List Mode | Up to 32 steps per group |
Expansion | 7508 (8-channel) / 7516 (16-channel) expansion boxes; up to 72 channels |
Interfaces | RS-232, Remote, USB Host, USB Device, EXT. I/O |
Remote Output Signals | Pass, Fail, HV Output, Testing |
Display | 4.3-inch TFT color display, 480 × 272 |
Power Supply | 90–264 VAC, 50/60 Hz ±5% |
Power Consumption | 300 VA |
Operating Environment | 5–40°C; 0–80% RH |
Dimensions | 435 × 145 × 500 mm (W × H × D) |
Weight | 15 kg |
Applications | Transformers, motors, capacitors, inductors, wires, wave filters, HV harnesses, connectors and PCBs |
Hi pot Tester Microtest 7631 (8 Channel)
MICROTEST 7631 is a 3-in-1 test instrument that supports AC withstand voltage, DC withstand voltage, and insulation resistance testing functions. It has a maximum AC withstand voltage of 5000V with a leakage current of 30mA, a maximum DC withstand voltage of 6000V with a leakage current of 10mA, and a maximum insulation resistance of 12000MΩ. It provides 8 sets of testing channels and can be optionally equipped with the 7508/7516 multi-channel scanning box, allowing up to 72 sets of testing channels. It supports PC connection software for remote programming and storage of test data. It can also be linked to a barcode scanner for barcode scanning, facilitating production traceability management.
- 8 Channels
- Hi pot ACW 5KV/30mA
- Hi pot DCW 6KV/10mA
- Insulation 1KV/12000MΩ
- Arcing detection
- True RMS measurement circuit
- Measuring Time (0.1 ~ 999s)
- Adjustable ramp time (0.1 ~ 10s)
- Safety Switch(INTER LOCK)
- Option PC Link Software
- 7508/7516 (8/16 channels) expansion box
- Support AC 5000V, DC 6000V, Insulation Resistance 12GΩ
Specification | Details |
Model | 7631 |
Test Channels | 8 |
Product Type | 3-in-1 Hi-Pot / Safety Tester |
AC Hipot Output Voltage | 10 V–5000 V |
AC Voltage Resolution | 1 V |
AC Voltage Accuracy | ±(3% of setting + 5 V) |
AC Rated Current | 30 mA maximum |
AC Leakage Current | 0.001–31 mA |
AC Leakage Resolution | 0.001 mA |
AC Arcing Detection | 0–20 levels; level 1 is most sensitive |
DC Hipot Output Voltage | 10 V–6000 V |
DC Voltage Resolution | 1 V |
DC Voltage Accuracy | ±(3% of setting + 5 V) |
DC Rated Current | 10 mA maximum |
DC Leakage Current | 0.001–11 mA |
DC Leakage Resolution | 0.001 mA |
DC Arcing Detection | 0–10 levels; level 1 is most sensitive |
Insulation Resistance Voltage | 10–1000 V DC |
Insulation Resistance Range | 1–12000 MΩ |
IR Resolution | 1 MΩ |
IR Accuracy | 100–500 V: 1–1000 MΩ ±5%; 500–1000 V: 2–12000 MΩ ±5% |
Measuring Time | 0.1–999 s |
Measuring Time Resolution | 0.1 s |
Ramp Time | 0.1–10 s |
Measurement Circuit | True RMS |
Safety Switch | INTER LOCK |
Built-in Storage | 15 sets |
List Mode | Up to 32 steps per group |
Expansion | 7508 (8-channel) / 7516 (16-channel) expansion boxes; up to 72 channels |
Interfaces | RS-232, Remote, USB Host, USB Device, EXT. I/O |
Remote Output Signals | Pass, Fail, HV Output, Testing |
Display | 4.3-inch TFT color display, 480 × 272 |
Power Supply | 90–264 VAC, 50/60 Hz ±5% |
Power Consumption | 300 VA |
Operating Environment | 5–40°C; 0–80% RH |
Dimensions | 435 × 145 × 500 mm (W × H × D) |
Weight | 15 kg |
Applications | Transformers, motors, capacitors, inductors, wires, wave filters, HV harnesses, connectors and PCBs |