Chat with us
Skip to content

R2 Socket Adaptor - DL1601

SKU : SKDL1601
MAKE : DI-LOG
MODEL : DL1601
AVAILABILITY : IN STOCK
Original price SAR 70.00 - Original price SAR 70.00
Original price
SAR 70.00
SAR 70.00 - SAR 70.00
Current price SAR 70.00
(Excluding VAT)

R2 Socket Adaptor - DL1601

Di-LOG DL1601 R2 Socket Adaptor is designed for convenient electrical continuity testing of socket outlets without the need to remove the socket from the wall. Simply plug the adaptor into a standard 13A socket and connect it to a compatible multifunction installation tester using the standard 4mm connectors.

It enables electrical professionals to perform R2 and R1+R2 continuity tests efficiently, making it a useful accessory for electrical installation inspection, testing and verification.

With compatibility across most multifunction testers featuring standard 4mm test connections and CAT III 300V safety compliance, the DL1601 provides a practical solution for routine electrical testing and maintenance.

Key Features

  • Enables R2 and R1+R2 continuity testing without removing the socket from the wall.

  • Standard 4mm connectors compatible with most multifunction installation testers.

  • Simple plug-in connection to standard 13A socket outlets.

  • Saves time during electrical installation testing.

  • CAT III 300V safety compliance in accordance with IEC 1010.

  • Compact and convenient design for electrical inspection applications.

1. What is the Di-LOG DL1601 used for?

The DL1601 is an R2 socket adaptor used for performing R2 and R1+R2 continuity tests on socket outlets without removing the socket from the wall.

2. Can the DL1601 perform R1+R2 continuity testing?

Yes. The adaptor supports both R2 and R1+R2 continuity testing when used with a compatible multifunction installation tester.

3. Is it necessary to remove the socket from the wall during testing?

No. The DL1601 allows testing through the existing 13A socket outlet without removing the socket from the wall.

4. Which testers are compatible with the DL1601?

It features standard 4mm connectors and is compatible with most multifunction installation testers that support these connections.

5. What type of socket does the DL1601 support?

It is designed to connect to a standard 13A socket outlet.

6. What is the safety category of the DL1601?

The DL1601 complies with IEC 1010 safety requirements and is rated CAT III 300V.

7. Is the DL1601 a standalone multifunction tester?

No. It is an accessory adaptor and must be used with a compatible multifunction installation tester.

8. What are the typical applications of the DL1601?

It is suitable for electrical installation inspections, socket outlet continuity testing, electrical maintenance and verification work.

R2 Socket Adaptor - DL1601

Di-LOG DL1601 R2 Socket Adaptor is designed for convenient electrical continuity testing of socket outlets without the need to remove the socket from the wall. Simply plug the adaptor into a standard 13A socket and connect it to a compatible multifunction installation tester using the standard 4mm connectors.

It enables electrical professionals to perform R2 and R1+R2 continuity tests efficiently, making it a useful accessory for electrical installation inspection, testing and verification.

With compatibility across most multifunction testers featuring standard 4mm test connections and CAT III 300V safety compliance, the DL1601 provides a practical solution for routine electrical testing and maintenance.

Key Features

  • Enables R2 and R1+R2 continuity testing without removing the socket from the wall.

  • Standard 4mm connectors compatible with most multifunction installation testers.

  • Simple plug-in connection to standard 13A socket outlets.

  • Saves time during electrical installation testing.

  • CAT III 300V safety compliance in accordance with IEC 1010.

  • Compact and convenient design for electrical inspection applications.

1. What is the Di-LOG DL1601 used for?

The DL1601 is an R2 socket adaptor used for performing R2 and R1+R2 continuity tests on socket outlets without removing the socket from the wall.

2. Can the DL1601 perform R1+R2 continuity testing?

Yes. The adaptor supports both R2 and R1+R2 continuity testing when used with a compatible multifunction installation tester.

3. Is it necessary to remove the socket from the wall during testing?

No. The DL1601 allows testing through the existing 13A socket outlet without removing the socket from the wall.

4. Which testers are compatible with the DL1601?

It features standard 4mm connectors and is compatible with most multifunction installation testers that support these connections.

5. What type of socket does the DL1601 support?

It is designed to connect to a standard 13A socket outlet.

6. What is the safety category of the DL1601?

The DL1601 complies with IEC 1010 safety requirements and is rated CAT III 300V.

7. Is the DL1601 a standalone multifunction tester?

No. It is an accessory adaptor and must be used with a compatible multifunction installation tester.

8. What are the typical applications of the DL1601?

It is suitable for electrical installation inspections, socket outlet continuity testing, electrical maintenance and verification work.

Compare products

{"one"=>"Select 2 or 3 items to compare", "other"=>"{{ count }} of 3 items selected"}

Select first item to compare

Select second item to compare

Select third item to compare

Compare