50ADM-P Secondary Current Injection Test Set - T&R

The 50ADM-P Secondary Current Injection Test Set delivers unmatched precision and reliability for testing protective relays, circuit breakers, and other critical components. With a blend of high performance, advanced features, and user-centric design, the 50ADM-P is an indispensable tool for professionals across industries. The instrument offers high-accuracy current and voltage outputs, enabling testing currents up to 50A and voltages up to 18V.

Whether you are conducting primary injections, stability tests, or detailed circuit breaker analyses, this test set ensures your testing is precise and reliable. Experience true RMS metering that delivers accurate readings with single-cycle precision. The advanced timing system provides automatic range selection for trip, reset, and reclose timing, offering a resolution down to 1ms. This level of detail is crucial for validating equipment performance and ensuring compliance with industry standards.

  • 0-50A output current
  • True RMS metering with 1 cycle capture
  • Variable auxiliary AC voltage/current output with phase shift
  • Auxiliary metering input V, f, φ, Z, P, S, PF, CT ratio
  • Variable auxiliary output 12-220VDC
  • Multi-function auto-range timing system
  • Current limit mode for fine control
  • Data storage to USB memory key including waveform & THD
  • USB keyboard interface
  • Automatic mains voltage selection

1. What is the T&R 50ADM-P used for?
It is used for secondary current injection testing of protective relays and electrical protection systems.

2. What is the maximum output current?
The 50ADM-P can provide up to 50 A of test current.

3. What is the maximum main output voltage?
The main output provides up to 18 V.

4. What type of relays can it test?
It can test overcurrent, earth-fault, under/over-voltage, directional power, negative-sequence, IDMT and other protection relays.

5. Does it provide True RMS measurement?
Yes. It features True RMS metering with single-cycle capture.

6. Does it have an integrated timer?
Yes. It has an automatic-ranging timer for measuring trip, reset and reclose times, with resolution down to 1 ms.

7. Does it provide auxiliary AC output?
Yes. The auxiliary AC output provides adjustable voltage/current with phase and frequency control.

8. Does it provide auxiliary DC output?
Yes. It provides a variable DC output from 12 to 220 V for powering the relay under test.

9. Can test results be saved?
Yes. Test results, waveforms and harmonic analysis data can be stored on a USB memory device.

10. Is the 50ADM-P suitable for field testing?
Yes. It is designed as a compact and portable relay test set. The main unit weighs approximately 13.2 kg.

50ADM-P Secondary Current Injection Test Set - T&R

The 50ADM-P Secondary Current Injection Test Set delivers unmatched precision and reliability for testing protective relays, circuit breakers, and other critical components. With a blend of high performance, advanced features, and user-centric design, the 50ADM-P is an indispensable tool for professionals across industries. The instrument offers high-accuracy current and voltage outputs, enabling testing currents up to 50A and voltages up to 18V.

Whether you are conducting primary injections, stability tests, or detailed circuit breaker analyses, this test set ensures your testing is precise and reliable. Experience true RMS metering that delivers accurate readings with single-cycle precision. The advanced timing system provides automatic range selection for trip, reset, and reclose timing, offering a resolution down to 1ms. This level of detail is crucial for validating equipment performance and ensuring compliance with industry standards.

  • 0-50A output current
  • True RMS metering with 1 cycle capture
  • Variable auxiliary AC voltage/current output with phase shift
  • Auxiliary metering input V, f, φ, Z, P, S, PF, CT ratio
  • Variable auxiliary output 12-220VDC
  • Multi-function auto-range timing system
  • Current limit mode for fine control
  • Data storage to USB memory key including waveform & THD
  • USB keyboard interface
  • Automatic mains voltage selection

1. What is the T&R 50ADM-P used for?
It is used for secondary current injection testing of protective relays and electrical protection systems.

2. What is the maximum output current?
The 50ADM-P can provide up to 50 A of test current.

3. What is the maximum main output voltage?
The main output provides up to 18 V.

4. What type of relays can it test?
It can test overcurrent, earth-fault, under/over-voltage, directional power, negative-sequence, IDMT and other protection relays.

5. Does it provide True RMS measurement?
Yes. It features True RMS metering with single-cycle capture.

6. Does it have an integrated timer?
Yes. It has an automatic-ranging timer for measuring trip, reset and reclose times, with resolution down to 1 ms.

7. Does it provide auxiliary AC output?
Yes. The auxiliary AC output provides adjustable voltage/current with phase and frequency control.

8. Does it provide auxiliary DC output?
Yes. It provides a variable DC output from 12 to 220 V for powering the relay under test.

9. Can test results be saved?
Yes. Test results, waveforms and harmonic analysis data can be stored on a USB memory device.

10. Is the 50ADM-P suitable for field testing?
Yes. It is designed as a compact and portable relay test set. The main unit weighs approximately 13.2 kg.