{"title":"High Voltage Testing Primary","description":"\u003cp\u003eOur \u003cstrong\u003eHigh Voltage Testing Primary\u003c\/strong\u003e solutions are designed for precise testing of transformers, circuit breakers, and other primary electrical equipment. These tools ensure safety, accuracy, and compliance for high-voltage systems in industrial and utility applications.\u003c\/p\u003e","products":[{"product_id":"secondary-current-injection-test-kit-100adm-mk4","title":"Secondary Current Injection Test kit 100ADM MK4","description":"\u003cp\u003eThe 100ADM mk4 Secondary Current Injection Test Set provides commissioning and maintenance engineers with a flexible system for testing protective systems. So It has an easy to understand panel layout and a simple user interface.We can see the status of every function at a glance. And there are no complicated menus to navigate. The100ADM mk4\u003cstrong\u003e \u003c\/strong\u003ekeeps the familiar user interface of previous models. But adds a new metering system that accurately measures the \u003cstrong\u003eRMS of a single cycle\u003c\/strong\u003e. It also features a \u003cstrong\u003enew current limit mode \u003c\/strong\u003eto provide excellent control of shallow currents, even into low impedance loads. \u003cstrong\u003eThe current limit mode \u003c\/strong\u003ealso helps test self-powered overcurrent protection as fitted to many 11kV ring central units. \u003c\/p\u003e\n\n\u003cp\u003eThe unit has a range of outputs allowing injection of currents as low as a few mA and as high as 100A. Voltages up to 240V are available on the main outputs. \u003cstrong\u003e100ADM mk4\u003c\/strong\u003e Allows high impedance current relays and voltage relays for the testing.\u003c\/p\u003e\n\n\u003cp\u003eIt will provide four true RMS metering ranges for the full scale \u0026amp; trip level from the selected output. It considers all the Industry standard safety connectors used for input\/output for convenience, reliability, and safety. \u003c\/p\u003e\n\n\u003cp\u003eThe  27.3% of the sentences contain passive voice, which is more than the recommended maximum of 10% Secondary Current Injection Test Set is comprehensively protected by overcurrent. Duty cycle and thermal trips and keeps the user fully informed of any trip condition.\u003c\/p\u003e\n\n\u003cp\u003eA stabilised DC supply is provided to power the relay under test, along with an independently switched and isolated 110V AC output. \u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e0-100A output current\u003c\/li\u003e\n\t\u003cli\u003eTrue RMS metering with single cycle capture\u003c\/li\u003e\n\t\u003cli\u003eAuxiliary DC and AC output\u003c\/li\u003e\n\t\u003cli\u003eMulti-function auto-ranging timing system\u003c\/li\u003e\n\t\u003cli\u003eCurrent limit mode for fine control\u003c\/li\u003e\n\t\u003cli\u003eAutomatic mains voltage selection\u003c\/li\u003e\n\t\u003cli\u003eThermal and over-current protection\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"T\u0026R Test Equipment","offers":[{"title":"Default Title","offer_id":52005376655673,"sku":"SCIT-100A","price":46200.0,"currency_code":"SAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0983\/5669\/1257\/files\/secondary_current_injection_test_kit_100adm_mk4_882ed876-8502-4da6-8b26-c66239ec5d9f.jpg?v=1773290398"},{"product_id":"vacuum-integrity-tester-hightest-vabo-80-80kv-with-printer","title":"Vacuum Integrity Tester Hightest VABO-80 80kV with Printer","description":"\u003cp data-start=\"82\" data-end=\"514\"\u003eThe \u003cstrong data-start=\"86\" data-end=\"133\"\u003eHighTest VABO-80 80 kV Vacuum Bottle Tester\u003c\/strong\u003e is a high-performance diagnostic instrument designed for accurate testing of \u003cstrong data-start=\"211\" data-end=\"254\"\u003evacuum interrupters in circuit breakers\u003c\/strong\u003e. Engineered with advanced technology, it applies \u003cstrong data-start=\"304\" data-end=\"335\"\u003eDC test voltage up to 80 kV\u003c\/strong\u003e to evaluate leakage current and ensure the integrity of vacuum bottles, helping prevent failures in medium and high-voltage power systems. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"516\" data-end=\"889\"\u003eThis robust and portable tester offers \u003cstrong data-start=\"555\" data-end=\"596\"\u003efast, reliable, and automated testing\u003c\/strong\u003e, making it ideal for field engineers, maintenance teams, and utility professionals. With adjustable test voltage from \u003cstrong data-start=\"715\" data-end=\"747\"\u003e10 kV to 80 kV in 1 kV steps\u003c\/strong\u003e, users can perform precise insulation integrity testing tailored to different breaker specifications. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"891\" data-end=\"1295\"\u003eThe VABO-80 features a \u003cstrong data-start=\"914\" data-end=\"949\"\u003e4.3-inch TFT colour touchscreen\u003c\/strong\u003e, ensuring clear visibility in both bright and low-light environments. It includes a \u003cstrong data-start=\"1034\" data-end=\"1062\"\u003ebuilt-in thermal printer\u003c\/strong\u003e for instant test reports, along with internal memory and USB storage for efficient data management. Integration with HighTest’s \u003cstrong data-start=\"1191\" data-end=\"1207\"\u003eDMP software\u003c\/strong\u003e allows seamless analysis and reporting on a PC.\u003c\/p\u003e\n\u003cp data-start=\"1475\" data-end=\"1914\"\u003e \u003c\/p\u003e\n\u003ch2 data-section-id=\"17qfci6\" data-start=\"83\" data-end=\"141\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"86\" data-end=\"141\"\u003eWhy Do We Need to Test a Vacuum Bottle Interrupter?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"143\" data-end=\"526\"\u003eTesting a \u003cstrong data-start=\"153\" data-end=\"182\"\u003evacuum bottle interrupter\u003c\/strong\u003e is essential to ensure the safe and reliable operation of electrical power systems. Circuit breakers play a critical role in protecting equipment and personnel by interrupting fault currents quickly and effectively. If a breaker fails to operate at the correct moment, it can lead to \u003cstrong data-start=\"467\" data-end=\"525\"\u003eserious hazards, equipment damage, and costly downtime\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"528\" data-end=\"804\"\u003eOver time, even highly reliable circuit breakers can be affected by \u003cstrong data-start=\"596\" data-end=\"641\"\u003edust, moisture, and external contaminants\u003c\/strong\u003e that accumulate on the poles and the surface of the vacuum interrupter. These conditions may compromise insulation performance and reduce operational reliability.\u003c\/p\u003e\n\u003cp data-start=\"806\" data-end=\"1048\"\u003eMore critically, if \u003cstrong data-start=\"826\" data-end=\"862\"\u003eair leaks into the vacuum bottle\u003c\/strong\u003e, the interrupter loses its dielectric strength, making it unable to safely interrupt electrical faults. This condition can lead to \u003cstrong data-start=\"994\" data-end=\"1047\"\u003eflashovers, failures, and unsafe system operation\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"1050\" data-end=\"1161\"\u003eFor these reasons, regular testing using a \u003cstrong data-start=\"1093\" data-end=\"1144\"\u003evacuum integrity tester or vacuum bottle tester\u003c\/strong\u003e is necessary to:\u003c\/p\u003e\n\u003cul data-start=\"1162\" data-end=\"1349\"\u003e\n\u003cli data-section-id=\"1q57k2h\" data-start=\"1162\" data-end=\"1216\"\u003eVerify the vacuum condition inside the interrupter\u003c\/li\u003e\n\u003cli data-section-id=\"17r3qsh\" data-start=\"1217\" data-end=\"1253\"\u003eDetect leakage or loss of vacuum\u003c\/li\u003e\n\u003cli data-section-id=\"12if44v\" data-start=\"1254\" data-end=\"1292\"\u003eEnsure reliable fault interruption\u003c\/li\u003e\n\u003cli data-section-id=\"1q35qp0\" data-start=\"1293\" data-end=\"1349\"\u003eMaintain safety and compliance in electrical systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1351\" data-end=\"1551\"\u003eRoutine testing and maintenance of vacuum interrupters help prevent unexpected failures, improve system reliability, and extend the lifespan of circuit breakers in industrial and utility applications.\u003c\/p\u003e","brand":"Hightest Technology","offers":[{"title":"Default Title","offer_id":53761644953913,"sku":"VBHTVB80","price":46200.0,"currency_code":"SAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0983\/5669\/1257\/files\/Vacuum-Bottle-Tester-VABO-80B-80_kV-Vacuum-Bottle-Tester-with-built-in_Battery_Printer._a89e7b44-0bc9-4e4d-bc30-0c34716f66bb.jpg?v=1783766391"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0983\/5669\/1257\/collections\/cat_16727276021047.jpg?v=1773207950","url":"https:\/\/www.measure-mart.sa\/collections\/high-voltage-testing-primary.oembed","provider":"Measuremart Global Company","version":"1.0","type":"link"}